| High voltage reed relays |
"DOLAM" S.A. has produced:
|
High voltage reed relays
|

| High voltage reed relays are assigned to switch and separation high voltage circuits from 5kV to 19kV. There are produced 3 type of relays: - type K-55xH - leads of reed switches are performed by elastic HV cables, leads of coil are adapted to PCB mounting,
- type K-56xH and R56x - all leads of relay are adapted to PCB mounting.
|
Basic parameters of relays type K-55xH, K-56xH and R-56x see below. More information are in data sheet in section Documentation » Data sheets. |
 |
The comparative chart of technical parameters of high voltage reed relays type K-55xH, K-56xH, R-56x |
 |
| Technical data |
Unit |
Type of reed relays |
K-551H K-561H R-561 |
K-552H K-562H R-562 |
K-553H |
K554H |
K-555H |
K-556H |
| Contact form |
|
normally open (type A) |
| Switching power |
max |
W |
50 |
10 |
| Breakdown voltage |
min |
kVDC |
7 |
10 |
14 |
17 |
18 |
19 |
| Switching voltage |
max |
kV |
5 |
7.5 |
10 |
12 |
| Switching current |
max |
A |
2 |
1 |
| Contact resistance |
max |
mΩ |
150 |
| Coil normal working voltage |
|
VDC |
5/6/12/24 |
| Pull-in voltage |
max |
VDC |
4/4.5/9/18 |
| Drop-out voltage |
min |
VDC |
0.5/0.6/1/2 |
| Nominal coil resistance |
|
Ω |
45/45/180/650 |
| Operate time including bounces |
max |
ms |
3.6 |
| Release time |
max |
ms |
0.5 |
Breakdown voltage coil-contact |
min |
kVDC |
15 |
30 |
|
 |
| Dimensions and terminal arrangements |
 |
K-55xH 
all dimension in mm |
K-56xH 
all dimension in mm |
R-56xH 
all dimension in mm |
|
 |
|
|
 |
|
back to top
|
|